A sequence-based primer and hydrolysis probe workbench for research assay development.
Works from supplied unambiguous DNA, not a microorganism-name lookup. No universal coverage or diagnostic validation is claimed. Database-wide specificity, thermodynamic structure checks and experimental validation remain separate review steps.
01 / DEFINE THE TARGET
Start with a reference sequence.
Files stay in your browser. Plain text only; maximum 150 KB. No archives, PDFs or executable files.
Design filters and search limits
Primers: 18–24 nt, 40–60% GC, estimated Tm 55–65°C, pair ΔTm <3°C. Internal probe: 20–30 nt, 35–65% GC, no 5′ G, estimated Tm 5–10°C above the higher primer Tm. Runs longer than four identical bases are excluded. Probe sites do not overlap primer sites.
Bounded heuristic search: up to 220 forward and 220 reverse candidates; probe search in the best 150 preliminary pairs; up to 10 distinct amplicon boundaries. A zero-result search does not establish that no suitable assay exists. No degenerate bases, transcript/exon design, multiplex optimisation or genome retrieval is implemented.
02 / LOCAL BIOINFORMATICS
Inspect the candidates.
Generate candidates to see coordinates, sequences and design metrics.
Optional comparison FASTA panel
Paste intended target variants or non-target sequences. This check counts exact oligo matches on both strands only; it does not align genomes, tolerate mismatches, predict off-target amplicons or establish inclusivity/exclusivity.
03 / DOCUMENT THE DECISION
Build a reviewable order worksheet.
Export a draft at any time. A reviewer-attested worksheet requires all checklist items, reviewer name, reference metadata and evidence notes. A checkbox records a human attestation—it does not run the external check.
These are worksheet fields, not recommendations. Reporter/quencher pairing, instrument channels, blocking and purification must be confirmed with the supplier. Plain sequences are 5′→3′; modifications are separate columns.
Draft · review incomplete.
Generic CSV worksheet, not an automatic supplier order or guaranteed bulk-import format. Confirm all fields with your supplier. Exports remain research candidates; reviewer attestation is not assay validation.
04 / GUIDANCE REVIEWED · 2 NOVEMBER 2026
Methods and evidence.
MIQE 2.0 · 2025
The revised research reporting guidelines cover assay design, sequence identification, specificity, controls and performance validation. This checklist supports documentation; it is not MIQE certification or regulatory approval.
Use an appropriate template accession and database search scope. Record databases, organism filters, settings and date. This app does not submit sequences to NCBI or claim that a BLAST search has run.
OligoLab 1.0 implements SantaLucia-style DNA nearest-neighbour estimates with monovalent salt correction (1–500 mM) and specified strand concentration. Self-complementary sequences receive a symmetry correction. It does not run Primer3. Contiguous complement lengths are simple flags, not ΔG calculations or hairpin predictions.
Guidance snapshot, not a live guideline feed. A qualified scientist must assess current requirements for the intended application. RNA assays require additional reverse-transcription design and validation. No clinical result interpretation is implemented.